Analog Devices Inc. AD7793BRUZ

AD7793BRUZ


  • Manufacturer: Analog Devices Inc.
  • CONEVO NO: AD7793BRUZ
  • Package: 16-TSSOP (0.173
  • Datasheet: PDF
  • Stock: In stock
If you have any question, please feel free to contact with us.We will reply you within 24 hours.

Details

Tags

Parameters
Series -
Moisture Sensitivity Level (MSL) 1 (Unlimited)
RoHS Status ROHS3 Compliant
Package / Case 16-TSSOP (0.173", 4.40mm Width)
Mfr Analog Devices Inc.
Mounting Type Surface Mount
Operating Temperature -40°C ~ 105°C
Input Type Differential
Configuration MUX-ADC
Supplier Device Package 16-TSSOP
Number of Inputs 3
Number of Bits 24
Number of A/D Converters 1
Architecture Sigma-Delta
Reference Type External, Internal
Data Interface SPI, DSP
Sampling Rate (Per Second) 470
Voltage - Supply, Analog 2.7V ~ 5.25V
Voltage - Supply, Digital 2.7V ~ 5.25V
Ratio - S/H:ADC -
Features PGA
Package Tube
Product Status Active
Base Product Number AD7793
REACH Status REACH Unaffected
Standard Package 96
ECCN EAR99
HTSUS 8542.39.0001

AD7793BRUZ: High-Precision, Low-Power 24-Bit Σ-Δ ADC for Industrial Sensing

The AD7793BRUZ is a high-precision, low-power 24-bit Σ-Δ analog-to-digital converter (ADC) designed for industrial and instrumentation applications requiring high resolution and noise immunity.   Housed in a 16-lead TSSOP package, it operates with a single 2.7 V to 5.25 V supply and consumes just 400 µA of current (typical), making it ideal for battery-powered or energy-efficient systems.   The device features three differential analog inputs, an integrated low-noise programmable gain instrumentation amplifier (PGA), and an on-chip precision reference with ±10 µV initial accuracy.   Its Σ-Δ architecture enables excellent linearity (±15 ppm INL) and supports data rates from 4.17 Hz to 470 Hz, configurable via SPI interface.

AD7793BRUZ Low-Power Precision ADC Key Features

● 24-Bit Resolution with Low Noise: Achieves up to 23-bit effective resolution with 40 nV RMS noise at 4.17 Hz update rate (gain = 64).

● Flexible Input Configuration: Three differential channels with PGA gains up to 128, allowing direct connection to low-level sensors like thermocouples, RTDs, and bridge transducers.

● Integrated Precision Components: Includes a 2.5 V internal reference (4 ppm/°C drift) and a bias voltage generator for offset adjustment.

● Low-Power Modes: Consumes only 1 µA in power-down mode, extending battery life in portable devices.

● Robust Clocking Options: Supports internal or external clocks, with 50/60 Hz rejection for noise-immune operation.

● Industrial-Grade Temperature Range: Operates from -40°C to +105°C, ensuring reliability in harsh environments.

 24-Bit Sigma-Delta ADC Applications

● Industrial Process Control: Precision measurement of pressure, temperature, and weight in PLCs and HMI systems.

● Medical Instrumentation: Blood analyzers, patient monitors, and portable diagnostic devices requiring microvolt-level sensitivity.

● Smart Sensors: IoT nodes for environmental monitoring (e.g., gas analysis, humidity sensing) and predictive maintenance.

● Portable Test Equipment: 6-digit DVMs, oscilloscopes, and data loggers benefiting from its high resolution and low power.

Advantages of Selection

● Simplified System Design: The on-chip PGA and reference eliminate the need for external amplification and voltage sources, reducing BOM cost and PCB footprint.

● High Accuracy and Stability: ±10 µV reference initial error and 4 ppm/°C drift ensure long-term measurement reliability.

● SPI Interface Flexibility: Compatible with 3-wire, QSPI, and MICROWIRE protocols, easing integration with microcontrollers like STM32, MSP430, and PIC.

● Industry-Proven Performance: Trusted in applications demanding traceable calibration and compliance with industrial standards (e.g., IEC 61010 for safety).


Contact Information